Vanderbilt University Medical Center Floor Slab

Vanderbilt Header
CTLGroup performed an independent evaluation of the condition of a mechanical room floor slab and adjacent exterior plaza structural slab located on Level 2 of the hospital building on the medical campus.

CTLGroup conducted a document review relating to the design and construction of the floor slab. A field investigation utilizing non-destructive testing was performed to evaluate the extent of concrete delamination, spalling and cracking in the mechanical room structural slab. Sample cores were collected for petrographic and chemical tests. A comprehensive report summarized CTLGroup’s evaluation and findings with recommendations for repairs.